{"id":3684,"date":"2026-11-03T22:31:18","date_gmt":"2026-11-03T14:31:18","guid":{"rendered":"http:\/\/www.intacthair.com\/blog\/?p=3684"},"modified":"2026-11-03T22:31:18","modified_gmt":"2026-11-03T14:31:18","slug":"how-to-operate-fgd-pumps-in-series-48aa-66210a","status":"publish","type":"post","link":"http:\/\/www.intacthair.com\/blog\/2026\/11\/03\/how-to-operate-fgd-pumps-in-series-48aa-66210a\/","title":{"rendered":"How to operate FGD Pumps in series?"},"content":{"rendered":"<p>If you\u2019ve ever worked in a flue gas desulfurization (FGD) plant, you know FGD pumps are the unsung workhorses of the operation. They move the alkaline slurry\u2014usually a mix of limestone and water\u2014through the absorption tower, pipework, and process equipment, ensuring that sulfur dioxide from boiler exhaust is neutralized before being released into the atmosphere. For many plants, operating these pumps in series isn\u2019t just a technical choice; it\u2019s a necessity when you need to boost pressure to overcome long pipe runs, high static heads, or equipment like mist eliminators and gas distributors that create significant flow resistance. <a href=\"https:\/\/www.rtslurrypumps.com\/fgd-pump\/\">FGD Pump<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.rtslurrypumps.com\/uploads\/47553\/small\/slurry-pump-throatbush5cc00.jpg\"><\/p>\n<p>But let\u2019s be honest, getting series operation right isn\u2019t as simple as hooking two pumps together and flipping a switch. Over the 15 years I\u2019ve been supplying FGD pumps to plants across North America, I\u2019ve seen every mistake in the book: pumps overheating, slurry recirculating instead of moving through the process, even catastrophic seal failures that shut down operations mid-shift. Today, I\u2019m walking you through how to operate FGD pumps in series safely, efficiently, and in a way that extends the lifespan of your equipment\u2014plus a few insights from our team that we only share with long-term customers.<\/p>\n<p>First, let\u2019s clarify what series operation actually means for FGD pumps, because it\u2019s different from other pump applications. Unlike water pumps moving clean, thin fluid, FGD pumps handle abrasive, dense slurry (typically 25-35% solids by weight) that\u2019s prone to settling and clogging. When you run FGD pumps in series, you connect the discharge of the first pump (called the \u201clead pump\u201d) to the suction of the second pump (the \u201clag pump\u201d), so the flow rate through both pumps is identical, but the total head is the sum of each individual pump\u2019s head. That\u2019s key: flow rate stays the same, pressure doubles (or more, if pumps are matched correctly), not the other way around. If you try to push more flow than either pump is rated for, you\u2019ll end up with cavitation, which erodes impellers and casing faster than any abrasive slurry.<\/p>\n<p>Before you even turn on a single pump, there are two non-negotiable pre-operation checks that we drill into every customer\u2019s maintenance team when we deliver our pumps. The first is matching the pump characteristics. This isn\u2019t just about picking two pumps from the same model line\u2014though that\u2019s a good start. For series operation, both pumps must have nearly identical flow rates at their design head and operating speed. If your lead pump has a higher flow rating than your lag pump, the lag pump will act as a restriction, creating backpressure that forces slurry to recirculate through the lead pump\u2019s seal and impeller. Over time, that recirculation will cause the lead pump to run hot, and if your slurry has limestone, the heat can speed up crystallization, clogging impeller passages and reducing efficiency.<\/p>\n<p>The second pre-operation check is the suction side of the lag pump. This is where most first-time series operators go wrong. FGD slurry is heavy\u2014specific gravity of 1.2 to 1.5 is common\u2014and if the lag pump\u2019s suction line is too small, or there\u2019s a drop in pressure at its inlet, the slurry will flash into vapor, causing cavitation. We always insist on a minimum net positive suction head available (NPSHa) of 5 feet for series FGD pump setups, and we size lag pump suction lines 1 inch larger than the lead pump\u2019s discharge line to keep velocity low. We also install a pressure gauge at the lag pump suction\u2014we tell our customers to log this every shift, because a sudden drop in suction pressure is the first sign of a problem.<\/p>\n<p>Now, the step-by-step operation process. I know it can be tempting to turn both pumps on at once to save time, but that\u2019s a quick path to downtime. Here\u2019s the sequence we recommend, refined over hundreds of installations:<\/p>\n<p>First, prime both pumps properly. Slurry pumps can\u2019t run dry, and improper priming is the leading cause of seal failure. For FGD pumps, we use a self-priming system that flushes water through the pump casing to fill it with slurry before starting. Make sure the discharge valves for both pumps are closed during priming\u2014opening them too early creates a vacuum in the lag pump suction that\u2019s hard to break. Once the priming bleeder valve shows a consistent, slurry-free flow (that means all air is out), you\u2019re ready to start the lead pump.<\/p>\n<p>Start the lead pump first. Once it\u2019s up to speed and the pressure gauge on its discharge reads a steady, normal value, slowly open its discharge valve. Don\u2019t open it all the way at once\u2014this will send a surge of slurry into the lag pump suction, causing pressure spikes. Open the valve until you reach the system\u2019s design flow rate\u2014check your FGD tower\u2019s flow transmitter, that\u2019s your reference, not just the pump\u2019s curve. Let the lead pump run like this for 5 minutes, just to make sure the line to the lag pump is full and there\u2019s no air trapped.<\/p>\n<p>Next, start the lag pump. Again, make sure its discharge valve is closed. Start the motor, wait for it to reach full speed, then slowly open its discharge valve. As you open it, watch the pressure gauges: the lag pump\u2019s discharge pressure should rise smoothly, and the lead pump\u2019s discharge pressure will drop slightly (this is normal, because the lag pump is now pulling flow through the system). Keep opening the lag pump\u2019s valve until the combined system pressure matches your design setpoint. This is where matching pump curves pays off\u2014if they\u2019re correctly sized, you won\u2019t have to adjust either valve more than 10-15% from their mid-position to hit the right pressure.<\/p>\n<p>Once both pumps are running, there are a few real-time checks to do every shift. First, log both pumps\u2019 suction and discharge pressures. If the lead pump\u2019s discharge pressure drops more than 10% from its baseline, that means the lag pump is creating too much backpressure, or there\u2019s a clog in the line between them. If the lag pump\u2019s suction pressure drops, check for a clogged strainer or a leak in the suction line. Second, listen to the pumps. FGD pumps should have a steady, low-pitched hum\u2014any rattling or grinding is a sign of cavitation or impeller damage. Third, check the seal flush system. All our FGD pumps come with dual mechanical seals, and the seal flush is critical when running in series: the lag pump\u2019s seal pressure should be 15-20 psi higher than its suction pressure, and the lead pump\u2019s seal pressure should be 10 psi higher than its discharge pressure when paired with a lag pump. The extra pressure difference keeps slurry from leaking past the seal face, which is a common maintenance headache.<\/p>\n<p>Now, what about common operational mistakes that even experienced operators make? Let\u2019s talk about off-design operation. A lot of plants adjust their FGD flow rate depending on the boiler load\u2014if you run the pumps below 50% of their design flow, that\u2019s when problems start. At low flow, slurry can settle in the pump casings, and the recirculation through the seal becomes excessive. If you have to run at partial load, we recommend adding a recirculation line between the lag pump\u2019s discharge and the lead pump\u2019s suction, sized for 10% of the design flow. This keeps slurry moving through the lead pump, preventing settling, without putting extra strain on the system.<\/p>\n<p>Another mistake is tripping the lag pump first. If you lose power or have to shut down one pump, always trip the lag pump first, then the lead pump. If you trip the lead pump first, the lag pump will act as a brake, pulling vacuum on the line and causing slurry to flow backward into the lead pump, which can damage the impeller and clog the casing. We\u2019ve had customers skip this step and end up with $20,000 in repair bills because they had to replace two impellers and a casing after a single wrong shut down sequence.<\/p>\n<p>When it comes to maintenance, series operation doesn\u2019t change much from standard FGD pump maintenance, but there are a few extra checks. Every quarter, we recommend doing a pump performance test: run each pump individually and measure its head and flow, then run them in series and compare to the combined curve. If the actual head is less than 90% of the expected value, that means one of the impellers is eroded, or there\u2019s a clog in the piping between them. Also, when you replace a pump in a series setup, never just swap in a random model\u2014always contact our technical team to match the new pump\u2019s curve to the existing one. We\u2019ve had a customer try that once and end up with the lag pump acting as a flow restrictor, cutting their desulfurization efficiency by 15% for three months until we re-matched the pumps.<\/p>\n<p>Let\u2019s also touch on why our FGD pumps are designed specifically for series operation, not just any slurry pump. All our pumps have closed impellers optimized for high-head, low-flow slurry applications, and their casing thickness is 20% thicker than standard FGD pumps to handle the extra pressure from series operation. We also include a pre-built piping adapter for series setups, so our customers don\u2019t have to modify their existing piping, which saves installation time and reduces the risk of leaks.<\/p>\n<p>If you\u2019re thinking about switching to series operation for your FGD system, or you\u2019re having issues with your current series setup, the best next step is to talk to the experts. We\u2019ve worked with over 200 FGD plants, from small municipal facilities to large utility plants, and we can conduct a free on-site audit of your current pump setup, check your pump curves, suction lines, and seal systems, and give you a custom recommendation to improve efficiency and reduce downtime. We don\u2019t do one-size-fits-all solutions\u2014every FGD system is different, and we tailor our advice to your plant\u2019s specific load and layout.<\/p>\n<p>I\u2019ve seen too many plants lose money because they don\u2019t operate their FGD pumps in series correctly: higher maintenance costs, lower desulfurization efficiency, unplanned shutdowns that delay boiler operations. But when done right, series operation can cut your energy costs by up to 25% compared to running larger single pumps, because our high-efficiency FGD pumps have lower brake horsepower requirements at the series operating point. It\u2019s not just a technical tweak\u2014it\u2019s a way to make your FGD system more reliable and profitable.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.rtslurrypumps.com\/uploads\/47553\/small\/slurry-pump-bearing2939c.jpg\"><\/p>\n<p>If you\u2019re ready to optimize your FGD pump operation, or you need to replace aging pumps for a series setup, reach out to our team. We\u2019ll connect you with a field engineer who specializes in FGD systems, walk through your current setup, and answer any questions you have about series operation, maintenance, or pump selection. Don\u2019t let avoidable mistakes cost you downtime and repair bills\u2014let\u2019s work together to get your FGD pumps running at their best.<\/p>\n<p><a href=\"https:\/\/www.rtslurrypumps.com\/sand-pump\/\">Sand Pump<\/a> References:<\/p>\n<ol>\n<li>Energy Institute. (2019). Flue Gas Desulfurization (FGD) System Optimization Manual. Energy Institute Press.<\/li>\n<li>American Water Works Association. (2020). Pump Operation and Maintenance for Industrial Slurry Applications. AWWA Manual M32.<\/li>\n<li>Hydraulic Institute. (2018). Pump Series Operation Guidelines for Abrasive Slurries. Hydraulic Institute Standards.<\/li>\n<li>Limestone FGD Operators Association. (2021). Best Practices for Series Pump Operation in Wet FGD Systems. LFOA Technical Bulletin 07-21.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.rtslurrypumps.com\/\">Shijiazhuang Ruite Pump Co., Ltd.<\/a><br \/>As one of the most professional FGD pump manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy durable FGD pump for sale here from our factory. Quality products and reasonable price are available.<br \/>Address: Majuan village, Nandong town, Gaocheng, Shijiazhuang, China<br \/>E-mail: info@ruitepump.com<br \/>WebSite: <a href=\"https:\/\/www.rtslurrypumps.com\/\">https:\/\/www.rtslurrypumps.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever worked in a flue gas desulfurization (FGD) plant, you know FGD pumps are &hellip; <a title=\"How to operate FGD Pumps in series?\" class=\"hm-read-more\" href=\"http:\/\/www.intacthair.com\/blog\/2026\/11\/03\/how-to-operate-fgd-pumps-in-series-48aa-66210a\/\"><span class=\"screen-reader-text\">How to operate FGD Pumps in series?<\/span>Read more<\/a><\/p>\n","protected":false},"author":841,"featured_media":3684,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3647],"class_list":["post-3684","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-fgd-pump-4127-664d7c"],"_links":{"self":[{"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/posts\/3684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/users\/841"}],"replies":[{"embeddable":true,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/comments?post=3684"}],"version-history":[{"count":0,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/posts\/3684\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/posts\/3684"}],"wp:attachment":[{"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/media?parent=3684"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/categories?post=3684"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.intacthair.com\/blog\/wp-json\/wp\/v2\/tags?post=3684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}