If you’ve ever stood in front of a bin full of hexagon head bolts—tight, six-sided fasteners used in everything from assembling backyard decking to securing industrial machinery—you’ve probably never stopped to ask: what is the electrical conductivity of a hexagon head? For most people, a hex head is just a tool to clamp two pieces of metal together, nothing more. But for me, as a hex head supplier who’s spent years sourcing, testing, and shipping these parts to construction teams, aerospace technicians, and electricians across North America, conductivity isn’t just a niche science question—it’s a detail that can make or break a project. Hexagon Head

A hexagon head, at its core, is a fastener: a head formed with six flat sides, paired with a threaded shank to pull components tight. Its conductivity isn’t a fixed number, either. It shifts based on what material the hex head is made from, how it’s manufactured, and even tiny surface treatments added for corrosion resistance. Let’s break this down, starting with the basics of electrical conductivity, then how it applies to the specific hex heads we supply, and why it matters for the people who buy them.
First, electrical conductivity is a measure of how well a material allows electric current to flow through it. The standard unit is siemens per meter (S/m), and it’s the inverse of resistivity—so a high conductivity means low resistance, and vice versa. Metals, which have a “sea” of free electrons that move easily when a voltage is applied, are some of the best conductors. Non-metals like rubber have almost no free electrons, so their conductivity is near zero, and they’re used to insulate wires. For fasteners, conductivity is usually measured as a percentage of pure copper’s conductivity, a common benchmark in manufacturing. Pure copper, for reference, has a conductivity of about 59.6 × 10^6 S/m, or 100% when used as a baseline for metal components.
Now, back to hexagons. The most common hex head material we work with is carbon steel. About 70% of the hex heads we ship are made from low-carbon steel, often called mild steel. Mild steel isn’t a top-tier conductor, but it’s far from the worst. Its conductivity hovers around 1.6 × 10^6 S/m, which translates to roughly 2.7% of pure copper’s conductivity. That might sound low, but it’s more than enough for most mechanical jobs. What many people don’t realize is that the manufacturing process for the hex head—how it’s formed from steel wire—can tweak that number a little. For example, hot-forging, the method we use for most standard hex heads, compacts the steel’s internal structure, aligning metal grains to create a more consistent electron path. That gives hot-forged hex heads a slightly higher conductivity than cold-forged or machined ones, where grain alignment might be disrupted by cutting or bending.
The 30% of hex heads we supply that are stainless steel are a different story. Stainless steel mixes iron with chromium (usually 10-20%) and sometimes nickel, which makes it rust-resistant but hurts conductivity. Austenitic stainless steel, the most common type for hex heads (304 and 316 grades), has a conductivity of only about 1.4 × 10^6 S/m, or roughly 2.3% of pure copper. Ferritic and martensitic stainless steels are a little better, around 2.3 × 10^6 S/m, but still way lower than carbon steel. That’s why electricians working on electrical bonding or grounding systems almost never use stainless steel hex heads—they need a conductor that can carry current safely, not one that will resist it and heat up.
Wait, but what about specialty hex heads? We also source brass hex heads for applications like plumbing fixtures and decorative hardware, and their conductivity is way higher. Brass is an alloy of copper and zinc, so its conductivity falls between the two: around 15.6 × 10^6 S/m, or about 26% of copper’s. Bronze hex heads, another specialty option, are slightly lower, around 10 × 10^6 S/m, or 17% of copper. For applications where conductivity matters—like lightning protection systems, electrical equipment enclosures, or even some vehicle wiring ties—these non-steel hex heads are the go-to choice, and their conductivity is a key spec we highlight for every custom order we fulfill.
But here’s a trickier part: the surface of the hex head. Many hex heads get a coating to prevent rust or improve appearance. Zinc plating, the most common coating for carbon steel hex heads, adds a thin layer of zinc that’s more conductive than steel, but because it’s so thin (usually 5-15 micrometers), it barely affects the overall conductivity of the hex head. A zinc-plated steel hex head will still test at around 2.7% of copper’s conductivity, almost identical to uncoated mild steel. Cadmium plating, once popular for aerospace hex heads, has a similar effect, though it’s less common now due to environmental regulations. For stainless steel hex heads, sometimes we add a passivation layer to improve corrosion resistance—this thin chromium oxide layer is an insulator, so it can drop conductivity by a small amount, but it’s rarely enough to matter for most applications.
Now, why does all this matter to someone ordering hex heads? Let’s take a recent example: a customer of ours who installs commercial rooftop solar panels. They were using standard zinc-plated carbon steel hex heads to secure the panels to the mounting racks, but they kept getting a “voltage rise” warning from their electrical testing equipment. The issue? The carbon steel hex heads were resisting the flow of stray electrical current from the panels to the ground, creating a small voltage difference across the mounting hardware. When they switched to brass hex heads for the grounding connections, the problem was fixed immediately. That’s a case where the conductivity of a hex head wasn’t just a technical detail—it was the difference between a safe, code-compliant installation and a costly shutdown.
Another example: a local construction company that builds steel-framed commercial buildings. They use hex head bolts to connect steel beams, and their engineers require the hex heads to have a minimum conductivity rating of 2.0 × 10^6 S/m. Why? Because steel-frame buildings need to act as a single Faraday cage to protect against lightning strikes. If the hex heads between beams are too resistive, current from a lightning strike won’t flow evenly through the frame, creating hot spots that can weaken the steel or start a fire. Our hot-forged carbon steel hex heads meet that exact spec, and we make a point of testing every batch to confirm it, so the customer doesn’t have to worry about failing electrical inspections.
I’ve heard some suppliers claim that hex head conductivity is “universal” for all metal hex heads, but that’s just not true. Last year, a small manufacturing company reached out to us complaining that the hex heads they’d bought from another vendor were causing electrical issues in their conveyor belt systems. When we tested a sample, we found the vendor had supplied cold-forged low-carbon steel hex heads, which had a conductivity of only 1.1 × 10^6 S/m—well below what was needed for their grounding circuits. They switched to our hot-forged hex heads, which hit 1.7 × 10^6 S/m, and the issue was gone. That’s why, as a supplier, we don’t just sell hex heads by the pound or the piece. We test every material, every manufacturing run, and every batch of coated hex heads to give our customers the accurate conductivity data they need.
It’s also worth noting that for most everyday applications—like securing a bookshelf, a fence, or a car bumper—conductivity doesn’t matter at all. Those hex heads just need to be strong enough to hold, and rust-resistant if they’re outside. For those jobs, a standard zinc-plated carbon steel hex head works perfectly, and you’ll never notice its conductivity. The demand for conductivity-specific hex heads comes from specialized trades: electricians, aerospace technicians, renewable energy installers, and industrial engineers who understand how fastener material impacts electrical systems.
If you’re in the market for hex heads, whether you’re a general contractor working on a small deck or a renewable energy firm designing a utility-scale solar farm, don’t just ask for “hex head bolts.” Ask about the material, the manufacturing process, and the conductivity rating. I’ve had customers come to us after months of problems because they chose the wrong hex head for their electrical needs, and I’d rather help them avoid that headache upfront. We test every batch in our in-house lab, so we can send you the exact conductivity data you need, no guesswork required.

At the end of the day, a hexagon head is more than six sides and a threaded shank. It’s a small part of a larger system, and its conductivity is a detail that can make a big difference, especially when electricity is involved. For us as a supplier, that means we don’t just store and ship fasteners—we provide data, expertise, and parts that meet the specific needs of every project. Whether you need carbon steel hex heads for general construction, brass hex heads for electrical bonding, or stainless steel hex heads for marine applications, we have the right parts, and the specs to back them up. If you’re looking for reliable hex heads with accurate conductivity data for your next project, get in touch with our team to discuss your needs.
Metering Blocks REFERENCES
- ASM International. (2017). Fastener Materials and Processes. ASM Handbook Volume 4: Materials Properties.
- Electrical Contacts Handbook. (2020). Conductivity of Common Fastener Alloys. IEEE Press.
- Nyman, J. (2018). Thermal and Electrical Properties of Hot-Forged vs. Cold-Forged Carbon Steel. Journal of Manufacturing Processes.
- International Organization for Standardization. (2021). ISO 898-1: Mechanical Properties of Fasteners Made of Carbon Steel and Alloy Steel.
Hangzhou Lingcheng Technology Co., Ltd.
Address: Room 1613, 16th Floor, Building 3, No. 99 Wangzhou Road, Liangzhu Street, Yuhang District, Hangzhou City, Zhejiang Province
E-mail: LCKJ0408@163.com
WebSite: https://www.lingchengelectric.com/